Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products News Exhibitions Exhibitors
Duct Temperature Sensors 0-10V

Duct Temperature Sensors 0-10V

FOB Price:
US 22-28 / Piece
Min.Order Quantity:
50 Piece/Pieces
Supply Ability:
500 Piece/Pieces per Month
Port:
Shanghai
Place of Origin:
Shanghai, China (Mainland)
Payment Terms:
L/C,T/T,Western Union,MoneyGram
Brand:
CH-BA
Products Model:
T-U-D-10
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: CH-BA

    Model Number: T-U-D-10

    Place of Origin: Shanghai, China (Mainland)

Packaging & Delivery

  • Packaging Details: carton
  • Delivery Detail: Shipped in 3 days after payment

Specifications

Air Duct Temperate Sensor Features    

·          Thermistor,PT or NI sensing elements to fit your system

·          Simple and secure installation

·          Wide range of temperature probes

·          Compact size and modern design

Applications

·          On return air ducts to measure heating/cooling return air

·          On supply air ducts to measure heating/cooling supply air

·          In heat exchangers and air handling units to control heating/cooling coils for temperature and humidity control

·          As frost protection sensor

Temperature Sensor

The sensor measures the temperature by use of a NTC, PT or NI sensing element. The sensing element is either a glass packed thermistor with a negative temperature coefficient or a platinum film sensor or a thin nickel layer on a ceramic substrate. Its resistance changes according to the temperature. The change follows a specified curve. Below is a list of available sensor elements, curves and accuracies:

 

Item name

Sensing element

Curve

Compatible with

N18

Thermistor 1.8k at 25 °C

Curve 5

TAC, CSI

N3

Thermistor 3k at 25 °C

Curve 6

Alerton

N10

Thermistor 10k at 25 °C

Curve 24

Hysine, Alerton,ALC, Delta,Trane, CSI

N11

Thermistor 10k at 25 °C

Curve 7

Andover, Invensys, Carrier, KMC

N20

Thermistor 20k at 25 °C

Curve 20

Honeywell

N100

Thermistor 100k at 25 °C

Curve 9

Siemens SBT

Tp1

PT100

0.3851ohm/K

Honeywell

Tp2

PT1000

3.851ohm/K

Johnson Control

TK5

NI1000

5000ppm/k

Siemens SBT

Ordering

Ordering number:TS-XX-D-YY

XX indicates the sensor element optional,see table above.

YY indicates the probe length. Standard probe length is 20 cm.

For example:TS-N10-D-20

-N10 indicates the sensor element is Thermistor 10k .

-20     indicates the probe length is 20 cm.

Duct probes should be installed directly on the duct, in an area where the air stream is well mixed:

·          Locate a supply air sensor two or three meters down stream from the nearest fan and coil.

·          Mount the return air sensor close to the air inlet but downstream from a return fan if one is present.

·          To install the sensor, assemble base plate and probe, then drill a 8 mm hole and two 3 mm holes on a diameter of 25 mm in the duct.

·          Use two self-tapping sheet metal screws to tighten the mounting circuit in the cover.

·          Connect the wires according to the wiring diagram to the measuring circuit in the cover:

o         The Thermistors require two conductors; normally 18ga unshielded twisted pair.

o         The PT100, PT1000 and NI1000 sensors come with each two terminal connectors in order to connect up to four conductors for compensating conductor resistance.

·          Assemble the cover with the mounting plate.

·          Insert the assembled probe through the center opening of the mounting plate into the air stream.

·          Tighten the horizontal screw on the mounting plate to fix the probe to the duct.


Technical Specification

Sensing Probe

Thermistor:

Range

Accuracy

NTC

-30----70°C

±0.5k

Platinum-Film:

Range

Accuracy

PT,  0.3851ohm/k

-30----70°C

±0.3k

Nickel Thin Layer

     Range

     Accuracy

NI, 5000 ppm/k

-30----70°C

±1k

Connection

Connection Terminals

2.5 mm2

Environment

Operation
Climatic Conditions
Temperature
Humidity

To IEC 721-3-3
class 3 K5
-4070°C
<95% r.h.

Transport & Storage
Climatic Conditions
Temperature
Humidity
Mechanical Conditions

To IEC 721-3-2 and IEC 721-3-1
class 3 K3 and class 1 K3
-4080°C
<95% r.h.
class 2M2

Standards

          conform according to
EMC Standard 89/336/EEC
EMEI Standard 73/23/EEC


EN 61 000-6-1/ EN 61 000-6-3

 

Automatic electrical controls for household and similar use

Special requirement on temperature dependent controls

EN 60 730 1

 

EN 60 730 2 - 9

Pollution Class

Normal acc. To EN 60 730,RoHS compliant

Degree of Protection

IP56 to EN 60 529

Safety Class

III (IEC 60536)

Housing Materials

       Cover & Mounting Plate
Probe

Fire proof ABS plastic

Stainless Steel

General

Dimensions [mm]

Cover: 42 x 112 x 88 (H x W x D)
Probe: ø 6 x 200 (Diameter x L)

Weight (including package)

135g

 

Package and Shipping

 

Sample Order

Order

OEM Order

Three work days 2 weeks 3 weeks

 

Port

Shanghai

 

 

 Specilizng in manufacturing products of HVAC for almost 10 years.

 Harsh process of production and strict testing system.

 High quality with competitive price.

♦ Delivery in time.

♦ Reply in 24 hours.

 

Please feel free to contact the supplier if you need more information or help.

 

 
  • Email to this supplier
  • To :
    Kitty Weng  |  Shanghai huikong Energy Source Co., Ltd
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Shanghai huikong Energy Source Co., Ltd Bussiness Type:  Manufacturer
Scale:  11 - 50 People
Country/Region:  China (Mainland)/Asia
Established:  
You May Like:
Duct Temperature Sensor 4-20mA

Indoor temperature and humidity sensor

Duct Temperature Sensors PT100

Room Temperature Sensor RTD PT100

Duct humidity temperature indicator

Duct Humidity Temperature Measurment outdoor

Immersion Temperature Sensor

Indoor humidity temperature measurement

NTC 10K Air Conditioner Temperature Sensor

<font color='red'>Duct</font> <font color='red'>Temperature</font> <font color='red'>Sensors</font> <font color='red'>0</font>-<font color='red'>10V</font>